SunnyCheck PermitsPermit guide
Submitting in North Miami Beach? Upload the package and get a fix-it list in minutes, before the building department sees it. Your first 3 checks are free.Pre-check my package

← All towns

North Miami Beach building permits

Miami-Dade County · rules last read 2026-10-13

The 9th Edition (2026) of the Florida Building Code takes effect Dec 31, 2026: applications submitted from that day must comply with it. Product approvals: Miami-Dade applies an NOA whose drawings name a code edition only to permits under that edition, so applications from Dec 31, 2026 need NOA revisions approved for the 9th Edition. From Jan 1, 2027 every underlayment under roof tile needs its own NOA (the yellow-stripe prescriptive option ends), and hip and ridge shingles need an NOA showing the UL 2375 test or the prescriptive cement attachment (Miami-Dade Product Control notices of July 31, 2026). Upload each NOA as downloaded from Product Control: its own pages and every stamped drawing sheet.

Roof replacement / re-roof

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Forms we fill for you

Window and exterior door replacement

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Hurricane shutters / storm panels

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Garage door replacement

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

A/C changeout (like for like)

What to submit

Depends on your job

When the job value is over $15,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Limits

A/C unit distance to the property line0 ft to 4 ft
Smallest (RS-5). 4 ft into the interior side yard: RS-1 8 ft -> 4 ft; RS-2 and RS-3 7.5 ft -> 3.5 ft; RS-4 5 ft -> 1 ft; RS-5 3 ft (single lot) -> at the line. One side yard must keep a clear 5 ft path; equipment at the house's finished floor elevation and...

Water heater

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Fence / gate

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Limits

Maximum fence height, side and rear6 ft
Residential side/rear yards
Maximum fence height, front yard4 ft
Residential front yard

Shed / accessory storage structure

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Limits

Maximum shed height10 ft
Maximum shed area100 sq ft
Shed setback, side3 ft to 8 ft
The district side setback: RS-5 3 ft (single lot), RS-4 5 ft, RS-2/RS-3 7.5 ft, RS-1 8 ft. By zoning district: RS-1 8 ft, RS-2 7.5 ft, RS-3 7.5 ft, RS-4 5 ft, RS-5 3 ft
Shed setback, rear5 ft
Not in the front yard; one per property.

Generator / LP tank

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Limits

Generator distance to the property line0 ft to 4 ft
Smallest (RS-5). 4 ft into the interior side yard: RS-1 8 ft -> 4 ft; RS-2 and RS-3 7.5 ft -> 3.5 ft; RS-4 5 ft -> 1 ft; RS-5 3 ft (single lot) -> at the line. One side yard must keep a clear 5 ft path; equipment at the house's finished floor elevation and...
Screening around the generatorRequired (wall, fence or hedge)
From view, by a wall or hedge

Swimming pool / spa (new)

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Limits

Pool setback, side and rear7.5 ft

Solar PV

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Driveway / pavers / walkway / approach

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Interior remodel / alteration (incl kitchen/bath/flooring)

What to submit

Depends on your job

When the job value is over $5,000, a Notice of Commencement must be recorded, posted at the job and a copy filed with the building department before the first inspection (F.S. 713.135).

Built from the building department's own checklists, forms and fee schedules, the county rules and Florida law. Rules change: confirm with the building department before you submit.